Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

ABB PLC/

ABB 1VCF339756S4918 Switch Spring Charging Motor

Brand:ABB PLC
Item No.:1VCF339756S4918
Product Origin:Sweden (SE)
Product Dimensions:120 × 105 × 85 mm
Product Weight:2.1kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO
Evaluation:

0.0
Points

  • Product Details
  • Product Applications
  • Product Advantages
  • Technical FAQs
  • Contact

1VCF339756S4918

Product Profile

The ABB 1VCF339756S4918 Switch Spring Charging Motor is a high-reliability motor assembly designed for spring-charging mechanisms in medium-voltage vacuum circuit breakers. Engineered to automatically recharge the closing spring after breaker operation, this motor plays a critical role in ensuring fast, dependable switching performance and maintaining system readiness under demanding electrical distribution conditions.

Designed for ABB VD4 and ADVAC 50kA circuit breaker platforms equipped with EL Twin operating mechanisms, the motor delivers consistent charging performance, long service life, and dependable operation in power generation, transmission, and industrial distribution systems.


Technical Specifications

ParameterSpecification
ManufacturerABB
Model Number1VCF339756S4918
Product TypeSwitch Spring Charging Motor
ApplicationMedium Voltage Circuit Breakers
FunctionAutomatic Closing Spring Charging
Compatible BreakersABB VD4 / ADVAC 50kA
Operating MechanismEL Twin
Auxiliary Voltage220–250 V AC/DC
Motor TypeGear-Driven Charging Motor
Installation PositionBreaker Operating Mechanism
Duty TypeIntermittent Industrial Duty
Operating EnvironmentIndoor Power Distribution Systems


Typical Applications

The 1VCF339756S4918 motor is widely utilized in medium-voltage switchgear systems where reliable spring charging is essential for circuit breaker operation:

  • Electrical substations
  • Industrial power distribution networks
  • Utility transmission facilities
  • Manufacturing plants
  • Petrochemical installations
  • Renewable energy projects
  • Data center power infrastructure
  • Critical power protection systems

Its dependable performance helps ensure circuit breakers remain ready for rapid switching operations whenever required.


Performance Benefits

Fast Spring Recharging

Automatically restores stored mechanical energy after each breaker operation, minimizing waiting time between switching cycles.

Reliable Breaker Readiness

Ensures the circuit breaker remains prepared for immediate closing operations under normal operating conditions.

Industrial-Grade Durability

Designed to withstand demanding electrical environments and long-term operational requirements.

Stable Charging Performance

Provides consistent spring charging regardless of frequent operational cycles.

Optimized for ABB Breakers

Specifically engineered for seamless integration with ABB VD4 and ADVAC switchgear systems.

Reduced Maintenance Requirements

Robust construction and precision components contribute to extended service intervals and improved system availability.

Enhanced Operational Efficiency

Supports dependable switchgear performance, helping maintain power system continuity and reliability.


Technical FAQs

1. What is the primary function of the 1VCF339756S4918 motor?

It automatically charges the closing spring mechanism of compatible ABB circuit breakers.

2. Which circuit breakers commonly use this motor?

It is designed for ABB VD4 and ADVAC 50kA vacuum circuit breakers equipped with EL Twin mechanisms.

3. What auxiliary voltage does the motor require?

The motor operates on 220–250 V AC/DC auxiliary power.

4. Why is spring charging important?

A charged spring stores the mechanical energy necessary for fast and reliable breaker closing operations.

5. Does the motor charge the spring automatically?

Yes, charging begins automatically when auxiliary power is available and the breaker mechanism requires recharging.

6. Is the motor suitable for industrial power systems?

Yes, it is specifically developed for medium-voltage industrial and utility applications.

7. Can frequent breaker operations affect motor performance?

The motor is designed to handle repeated charging cycles under normal operating conditions.

8. Does the motor require periodic maintenance?

Routine inspections are recommended as part of standard switchgear maintenance programs.

9. Can a failed charging motor affect breaker availability?

Yes, proper spring charging is essential for maintaining normal breaker operating capability.

10. Is professional installation recommended?

Installation and replacement should be performed by qualified electrical maintenance personnel familiar with medium-voltage equipment.


Sales and Business Development

Phone: +8617350837383
E-mail: [email protected]
Skype: +8617350837383
WhatsApp: +8617350837383
Business hours: We Provide Online Support 24/7
Address: Room 1001, Jiuzhou Commercial Building, Xiamen, Fujian Province, China

Leave a message