Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

ICS Triplex PLC/

ICS Triplex T8293 Power Distribution Unit

Brand:ICS Triplex PLC
Item No.:T8293
Product Origin:USA
Product Dimensions:79 x 285 x 109 mm
Product Weight:0.576 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO
Evaluation:

0.0
Points

  • Product Details
  • Product Applications
  • Product Advantages
  • Technical FAQs
  • Contact

Introduction
The ICS Triplex T8293 Power Distribution Unit (PDU) is a highly efficient and compact solution for distributing power to critical components within ICS Triplex control systems. This versatile unit ensures that all connected devices, I/O modules, and safety systems receive stable, continuous power, which is crucial for maintaining the operational integrity of industrial processes. The T8293 is designed for applications that demand high reliability and minimal downtime, making it ideal for industries such as oil & gas, power generation, chemical processing, and industrial automation. With its small footprint and robust performance, the T8293 ensures optimal power distribution in even the most demanding environments.


Technical Specifications

Parameter Specification
Model T8293 Power Distribution Unit
Type Power Distribution Module
Dimensions 79 x 285 x 109 mm
Weight 0.576 kg (1.27 lbs)
Input Voltage 24V DC
Power Output Multiple output channels
Power Consumption 10W max
Operating Temperature -40°C to 70°C
Environmental Rating IP20 (dust-protected)
Compliance CE, UL, CSA, Ex-certified

Applications
The ICS Triplex T8293 Power Distribution Unit is used in various industries where reliable and uninterrupted power distribution is crucial:

  • Oil & Gas: In the oil & gas industry, the T8293 ensures reliable power distribution to monitoring and control systems, reducing the risk of downtime and ensuring safety and compliance.

  • Power Generation: In power plants, the T8293 is essential for supplying power to critical infrastructure, such as turbines, generators, and auxiliary systems, helping optimize efficiency and minimize operational disruptions.

  • Chemical Processing: The T8293 guarantees stable power delivery to control systems and safety devices in chemical processing plants, ensuring continuous and safe operation of production lines.

  • Water Treatment: The PDU ensures reliable power supply to sensors, actuators, and control systems in water and wastewater treatment facilities, maintaining operational safety and regulatory compliance.

  • Industrial Automation: The T8293 distributes power across automation systems, supporting the smooth operation of production lines, robots, and automated machinery, and ensuring high system availability.


Advantages

  • Compact and Space-Efficient: With a size of 79 x 285 x 109 mm and a weight of just 0.576 kg, the T8293 is compact enough to fit into control panels and systems where space is at a premium, without compromising on power distribution performance.

  • Efficient Power Distribution: The T8293 provides multiple output channels, ensuring that all connected components receive reliable and stable power, thus reducing the likelihood of faults caused by power interruptions.

  • Wide Operating Temperature Range: The T8293 operates in a wide temperature range from -40°C to 70°C, making it suitable for use in both high-temperature and cold environments, typical in industrial settings.

  • Energy-Efficient: With a power consumption of only 10W max, the T8293 is designed to be energy-efficient, which contributes to lowering operational costs while maintaining reliable performance.

  • Durable Construction: With an IP20 rating, the T8293 is dust-protected, ensuring that it remains reliable and operational in environments with moderate levels of dust and contaminants.

  • Safety Certifications: The T8293 is Ex-certified and meets CE, UL, and CSA standards, ensuring that it complies with global safety and regulatory requirements for hazardous and explosive environments.


Technical FAQs

  1. What is the ICS Triplex T8293 Power Distribution Unit used for?
    The T8293 is used to distribute stable and reliable power to various components in ICS Triplex control systems, ensuring the uninterrupted operation of critical processes.

  2. What are the dimensions of the T8293?
    The T8293 has dimensions of 79 x 285 x 109 mm, providing a compact solution for space-constrained industrial environments.

  3. How much does the T8293 weigh?
    The T8293 weighs 0.576 kg (1.27 lbs), making it lightweight and easy to handle during installation and maintenance.

  4. What power supply does the T8293 require?
    The T8293 operates on a 24V DC power supply, which is standard in many industrial control systems.

  5. How many output channels does the T8293 support?
    The T8293 supports multiple output channels, allowing power to be distributed efficiently to a variety of connected devices and systems.

  6. What is the power consumption of the T8293?
    The T8293 has a maximum power consumption of 10W, making it an energy-efficient solution for industrial applications.

  7. What is the operating temperature range for the T8293?
    The T8293 operates in temperatures ranging from -40°C to 70°C, which allows it to function in a wide variety of industrial environments, from hot to cold locations.

  8. Is the T8293 suitable for hazardous environments?
    Yes, the T8293 is Ex-certified and meets CE, UL, and CSA safety standards, making it ideal for use in hazardous and explosive environments.

  9. What environmental protection does the T8293 offer?
    The T8293 has an IP20 rating, meaning it is protected against dust and other environmental contaminants, ensuring reliability in industrial settings.

  10. In which industries is the T8293 commonly used?
    The T8293 is commonly used in industries such as oil & gas, power generation, chemical processing, water treatment, and industrial automation, where reliable and uninterrupted power is essential for system performance.


Sales and Business Development

Phone: +8617350837383
E-mail: [email protected]
Skype: +8617350837383
WhatsApp: +8617350837383
Business hours: We Provide Online Support 24/7
Address: Room 1001, Jiuzhou Commercial Building, Xiamen, Fujian Province, China

Leave a message