Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

Woodward/

Woodward 9905-003 SPM-A Synchronizer

Brand:Woodward
Item No.:9905-003
Product Origin:Woodward
Product Dimensions:191 x 25 x 235 mm
Product Weight:1.68 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO
Evaluation:

0.0
Points

  • Product Details
  • Product Applications
  • Product Advantages
  • Technical FAQs
  • Contact


Product Overview

The Woodward 9905-003 SPM-A Synchronizer is an essential device for ensuring accurate synchronization in power generation and industrial systems. By aligning the phase, frequency, and voltage of generators with the grid or other power sources, the synchronizer plays a key role in improving system stability, protecting equipment, and ensuring smooth power distribution. With its compact design and robust performance, the SPM-A Synchronizer is ideal for a wide range of applications, from conventional power plants to renewable energy systems, oil & gas facilities, and marine power systems.

Technical Specifications

SpecificationDetails
ManufacturerWoodward
Model Number9905-003
Module TypeSynchronizer
FunctionGenerator Synchronization
System CompatibilityCompatible with Woodward and third-party systems
Operating Temperature-40°C to 70°C
Storage Temperature-40°C to 85°C
Dimensions191 mm × 25 mm × 235 mm
Weight1.68 kg


Applications in Distributed Control Systems

The Woodward 9905-003 SPM-A Synchronizer is a sophisticated synchronization device designed to ensure that generators or other power sources are correctly synchronized with the electrical grid or other generating units. By aligning phase, frequency, and voltage, the SPM-A Synchronizer ensures smooth connections and stable power generation, helping to avoid costly operational errors such as out-of-sync connections. It is especially useful in applications where power generation reliability is critical.

Typical deployment scenarios include:

  • Power Generation: In conventional and renewable power plants, the synchronizer is used to synchronize generators with the grid, ensuring that they operate in harmony with the electrical system, avoiding synchronization errors that could lead to equipment failure or grid instability.
  • Industrial Manufacturing: In industrial environments, the synchronizer ensures the proper integration of backup and primary generators, safeguarding machinery and production lines from power disruptions caused by phase mismatches.
  • Oil & Gas: In offshore and onshore oil platforms, the synchronizer ensures stable power generation and distribution by keeping backup generators and critical systems in sync with each other or the grid.
  • Renewable Energy: In wind farms, solar plants, and hydroelectric stations, the synchronizer ensures that energy generated by renewable sources is seamlessly integrated into the grid, optimizing energy distribution and improving grid stability.
  • Marine Applications: The synchronizer is essential in marine environments, where it ensures that shipboard generators are synchronized with shore power or with each other, maintaining the stability of onboard systems and equipment.
  • Microgrids: In microgrid setups, where multiple independent power sources are integrated into a local distribution network, the synchronizer ensures that these sources are properly synchronized before being connected to the main grid or to each other.

The Woodward 9905-003 SPM-A Synchronizer is a vital component for maintaining synchronization in critical power generation and distribution systems, reducing the risk of synchronization issues, and ensuring smooth system operations.


Operational Advantages

  • High Precision Synchronization: Ensures that the generator’s frequency, phase, and voltage are perfectly aligned with the grid or other generators, avoiding synchronization errors that could lead to downtime or equipment failure.
  • Robust Design for Harsh Environments: Built for industrial applications, the synchronizer can operate in demanding environments, withstanding electrical noise, temperature variations, and mechanical stresses.
  • Real-Time Monitoring and Adjustment: The synchronizer continuously monitors synchronization parameters, making real-time adjustments to ensure precise alignment at all times.
  • Protects Equipment: By preventing out-of-phase connections, the synchronizer helps avoid mechanical stress, electrical surges, and other damaging effects, extending the life of generators and connected equipment.
  • Space-Efficient: With dimensions of 191 mm × 25 mm × 235 mm and a weight of just 1.68 kg, the synchronizer is compact and ideal for installations where space is limited, ensuring minimal disruption to the existing system setup.
  • Versatile Compatibility: The synchronizer is compatible with a wide range of generators, control systems, and power sources, providing flexibility for integration in diverse power generation and industrial setups.
  • Simplified Integration: Designed for easy integration with both Woodward and third-party control systems, the synchronizer can be deployed quickly and seamlessly without complex setup procedures.
  • Increases System Reliability: The SPM-A Synchronizer helps maintain a reliable power supply by ensuring that all connected generators and power sources are synchronized, reducing the risk of power outages or disruptions.
  • Cost-Efficient: By preventing damage caused by improper synchronization, the synchronizer minimizes the need for costly repairs, downtime, and maintenance, offering long-term savings on operational costs.
  • User-Friendly Interface: The synchronizer features a straightforward interface, making it easy for operators to configure, monitor, and adjust synchronization parameters, improving operational ease.


Technical FAQs

  1. What is the primary function of the Woodward 9905-003 SPM-A Synchronizer?
    The SPM-A Synchronizer ensures that generators are properly synchronized with the grid or other generators by aligning their frequency, phase, and voltage.
  2. In which industries is the SPM-A Synchronizer used?
    It is commonly used in power generation, oil & gas, renewable energy, industrial manufacturing, marine applications, and microgrids.
  3. How does the SPM-A Synchronizer improve system reliability?
    By ensuring proper synchronization between generators and the grid, the synchronizer helps prevent synchronization errors that could disrupt power generation or damage equipment, improving overall system reliability.
  4. Is the synchronizer compatible with renewable energy systems?
    Yes, the SPM-A Synchronizer is widely used in renewable energy plants such as wind farms, solar plants, and hydroelectric stations, helping synchronize the power generated with the grid.
  5. Can the synchronizer be used in marine power systems?
    Yes, it is ideal for marine applications, ensuring that generators onboard a vessel are synchronized with shore power or other onboard generators for stable power operation.
  6. What types of generators are compatible with the SPM-A Synchronizer?
    The synchronizer is compatible with a wide range of generators and power systems, making it suitable for various applications across industries.
  7. Does the SPM-A Synchronizer protect generators from damage?
    Yes, by preventing out-of-phase connections, the synchronizer helps protect generators and connected equipment from electrical surges, mechanical stress, and other issues that could cause damage.
  8. How does the SPM-A Synchronizer handle synchronization in real-time?
    The synchronizer continuously monitors synchronization parameters and makes automatic adjustments in real-time, ensuring that the generators remain aligned with the grid or other units at all times.
  9. What is the advantage of using the SPM-A Synchronizer in industrial manufacturing?
    It ensures that backup and primary generators are synchronized, preventing power disruptions and protecting sensitive equipment from damage caused by improper synchronization.
  10. How does the synchronizer contribute to cost savings in power generation systems?
    By preventing synchronization-related damage to equipment and reducing downtime, the SPM-A Synchronizer helps lower maintenance costs and extend the life of the equipment, resulting in long-term savings.


Sales and Business Development

Phone: +8617350837383
E-mail: [email protected]
Skype: +8617350837383
WhatsApp: +8617350837383
Business hours: We Provide Online Support 24/7
Address: Room 1001, Jiuzhou Commercial Building, Xiamen, Fujian Province, China

Leave a message