Applications
The NKCL01‑100 INFI‑Net Cable is essential wherever robust communication is required within ABB Bailey INFI‑90 systems. Typical applications include:
-
Network linking between INFI‑90 controller racks and remote nodes
-
Distributed I/O communication backbones in process plants
-
Data exchange paths in petrochemical, refining, and power generation facilities
-
Redundant communication loops for enhanced system availability
-
Automation installations demanding high signal integrity
Its construction supports industrial communication needs where electromagnetic interference and environmental stress are common.
Advantages
The ABB Bailey NKCL01‑100 offers several benefits that contribute directly to system performance and reliability:
-
Highly Reliable Transmission: Shielding and correct impedance ensure clean, predictable signal transfer.
-
Industrial Durability: Designed to withstand temperature extremes and moisture exposure.
-
Flexible Installation: Cable flexibility aids in routing within cabinets, conduits, and machine frames.
-
Optimized for INFI‑Net: Built specifically to match the electrical and physical requirements of INFI‑Net networks.
-
Long Service Life: Rugged materials and construction extend operational lifespan in harsh environments.
These attributes make the NKCL01‑100 an ideal choice for systems that rely on consistent, noise‑resilient communication.
Technical FAQs
-
What is the intended use of the NKCL01‑100 cable?
It is used to connect INFI‑Net network components within ABB Bailey distributed control systems.
-
What is the standard length of this cable?
The base NKCL01‑100 comes in a 100 meter standard length; custom lengths can be obtained as needed.
-
What type of conductor does it use?
High‑purity stranded copper conductors provide reliable electrical performance.
-
How is the cable protected from noise and interference?
Dual shielding (foil plus braid) reduces electromagnetic interference and preserves signal quality.
-
What environmental conditions can the cable handle?
It operates reliably from –20 °C to 70 °C and can be stored between –40 °C and 85 °C.
-
Is this cable suitable for outdoor use?
While its jacket tolerates industrial environments, outdoor deployment should consider UV and moisture exposure specifics.
-
What is the nominal impedance?
The NKCL01‑100 maintains a nominal impedance of 120 Ω, appropriate for INFI‑Net communication.
-
Can it be used for redundant network topologies?
Yes, its performance supports redundant communication designs.
-
How flexible is the cable for installation?
Its construction provides good flexibility for routing in control panels and conduit systems.
-
Does this cable require special termination tools?
Standard industrial termination tooling is appropriate; correct connector match and shielding termination are recommended.